会员体验
专利管家(专利管理)
工作空间(专利管理)
风险监控(情报监控)
数据分析(专利分析)
侵权分析(诉讼无效)
联系我们
交流群
官方交流:
QQ群: 891211   
微信请扫码    >>>
现在联系顾问~
热词
    • 2. 发明授权
    • Linear-carrier phase-mask interferometer
    • 线性载波相位掩模干涉仪
    • US07777895B2
    • 2010-08-17
    • US11800840
    • 2007-05-08
    • Brian S. MedowerJames E. Millerd
    • Brian S. MedowerJames E. Millerd
    • G01B11/02
    • G01B9/0201G01B9/02022G01B9/02057G01B9/02065G01B9/02079G01B9/0209G01B9/02098G01B11/2441G01B11/25G01B2290/70G06T7/521
    • A phase-difference sensor measures the spatially resolved difference in phase between orthogonally polarized reference and test wavefronts. The sensor is constructed as a linear-carrier phase-mask aligned to and imaged on a linear-carrier detector array. Each adjacent element of the phase-mask measures a predetermined relative phase shift between the orthogonally polarized reference and test beams. Thus, multiple phase-shifted interferograms can be synthesized at the same time by combining pixels with identical phase-shifts. The multiple phase-shifted interferograms can be combined to calculate standard parameters such as modulation index or average phase step. Any configuration of interferometer that produces orthogonally polarized reference and object beams may be combined with the phase-difference sensor of the invention to provide single-shot, simultaneous phase-shifting measurements.
    • 相位差传感器测量正交极化参考和测试波前的相位的空间分辨差异。 传感器被构造为与线性载波检测器阵列对准并成像的线性载波相位掩模。 相位掩模的每个相邻元件测量正交极化参考和测试光束之间的预定相对相移。 因此,通过组合具有相同相移的像素,可以同时合成多个相移干涉图。 可以组合多个相移干涉图以计算标准参数,例如调制指数或平均相位步长。 可以将产生正交偏振的参考和物体光束的干涉仪的任何配置与本发明的相位差传感器组合以提供单次,同时的相移测量。
    • 5. 发明授权
    • Chromatic compensation in Fizeau interferometer
    • 斐索干涉仪中的色彩补偿
    • US07580135B2
    • 2009-08-25
    • US11821223
    • 2007-06-22
    • John Hayes
    • John Hayes
    • G01B9/02
    • G01B11/2441G01B9/02039G01B9/02057G01B9/02063
    • The focus of the collimating lens in the optical train of a Fizeau interferometer is adjusted to change the power of the test beam illuminating the transmission sphere. As a result, the rays can be made sufficiently perpendicular to the reference surface to eliminate the chromatic focus shift and non-common path errors produced by a light source of wavelength different from the design wavelength of the transmission sphere. By making the position of the collimating lens relative to the beam expander adjustable along the optical axis over some small range, illumination sources of various wavelength can be used in the same interferometer.
    • 调整Fizeau干涉仪的光学列中的准直透镜的焦点以改变照射透射球的测试光束的功率。 结果,可以使光线足够垂直于参考表面,以消除由与透射球的设计波长不同的波长的光源产生的色彩偏移和非共同路径误差。 通过使相对于光束扩展器的准直透镜的位置沿着光轴在一定范围内可调,各种波长的照明源可以在相同的干涉仪中使用。
    • 6. 发明申请
    • Chromatic compensation in Fizeau interferometer
    • 斐索干涉仪中的色彩补偿
    • US20070296978A1
    • 2007-12-27
    • US11821223
    • 2007-06-22
    • John Hayes
    • John Hayes
    • G01B11/02
    • G01B11/2441G01B9/02039G01B9/02057G01B9/02063
    • The focus of the collimating lens in the optical train of a Fizeau interferometer is adjusted to change the power of the test beam illuminating the transmission sphere. As a result, the rays can be made sufficiently perpendicular to the reference surface to eliminate the chromatic focus shift and non-common path errors produced by a light source of wavelength different from the design wavelength of the transmission sphere. By making the position of the collimating lens relative to the beam expander adjustable along the optical axis over some small range, illumination sources of various wavelength can be used in the same interferometer.
    • 调整Fizeau干涉仪的光学列中的准直透镜的焦点以改变照射透射球的测试光束的功率。 结果,可以使光线足够垂直于参考表面,以消除由与透射球的设计波长不同的波长的光源产生的色彩偏移和非共同路径误差。 通过使相对于光束扩展器的准直透镜的位置沿着光轴在一定范围内可调,各种波长的照明源可以在相同的干涉仪中使用。
    • 7. 发明授权
    • Pixelated phase-mask interferometer
    • 像素相位掩模干涉仪
    • US07230717B2
    • 2007-06-12
    • US10838694
    • 2004-05-04
    • Neal J. BrockJames E. MillerdJames C. WyantJohn B. Hayes
    • Neal J. BrockJames E. MillerdJames C. WyantJohn B. Hayes
    • G01B11/02G01B9/02
    • G01B9/02022G01B9/02057G01B9/02081G01B9/02083G01B2290/70
    • A phase-difference sensor measures the spatially resolved difference in phase between orthogonally polarized reference and test wavefronts. The sensor is constructed as a pixelated phase-mask aligned to and imaged on a pixelated detector array. Each adjacent pixel of the phase-mask measures a predetermined relative phase shift between the orthogonally polarized reference and test beams. Thus, multiple phase-shifted interferograms can be synthesized at the same time by combining pixels with identical phase-shifts. The multiple phase-shifted interferograms can be combined to calculate standard parameters such as modulation index or average phase step. Any configuration of interferometer that produces orthogonally polarized reference and object beams may be combined with the phase-difference sensor of the invention to provide, single-shot, simultaneous phase-shifting measurements.
    • 相位差传感器测量正交极化参考和测试波前的相位的空间分辨差异。 传感器被构造为与像素化检测器阵列对准并成像的像素化相位掩模。 相位掩模的每个相邻像素测量正交极化参考和测试光束之间的预定相对相移。 因此,通过组合具有相同相移的像素,可以同时合成多个相移干涉图。 可以组合多个相移干涉图以计算标准参数,例如调制指数或平均相位步长。 可以将产生正交极化参考和物体光束的干涉仪的任何配置与本发明的相位差传感器组合以提供单次同时相移测量。
    • 10. 发明授权
    • Synchronous frequency-shift mechanism in Fizeau interferometer
    • Fizeau干涉仪中的同步变频机构
    • US07675628B2
    • 2010-03-09
    • US11899883
    • 2007-09-07
    • James E. MillerdMichael North-Morris
    • James E. MillerdMichael North-Morris
    • G01B9/02
    • G01B9/02057G01B9/02002G01B9/02045G01B9/02065G01B9/0209G01B2290/70
    • An optical device for characterizing a test surface combines a Fizeau interferometer with a polarization frequency-shifting element. Two substantially collinear, orthogonally polarized beams having respective frequencies differing by a predetermined frequency shift are generated by the polarization frequency-shifting element and projected into the Fizeau optical cavity to produce a pair of test beams and a pair of reference beams, wherein the beams in each pair have orthogonal polarization states and have frequencies differing by the predetermined frequency shift. A second, substantially equal frequency shift is introduced in the Fizeau cavity on either one of the pairs of test and reference beams, thereby generating a four-beam collinear output that produces an interferogram without tilt or short-coherence light. The invention may also be implemented by reversing the order of the Fizeau cavity and the polarization frequency-shifting element in the optical train.
    • 用于表征测试表面的光学装置将Fizeau干涉仪与偏振频移元件组合。 通过偏振频移元件产生具有不同频率预定频移的两个基本上共线的正交偏振光束,并投射到菲索光学腔中以产生一对测试光束和一对参考光束,其中光束 每对具有正交偏振状态并且具有与预定频移不同的频率。 第二个基本上相等的频移在Fizeau腔中的任一个测试和参考光束中被引入,从而产生产生没有倾斜或短相干光的干涉图的四光束共线输出。 本发明还可以通过使光纤列中的Fizeau腔和极化频移元件的顺序颠倒来实现。