会员体验
专利管家(专利管理)
工作空间(专利管理)
风险监控(情报监控)
数据分析(专利分析)
侵权分析(诉讼无效)
联系我们
交流群
官方交流:
QQ群: 891211   
微信请扫码    >>>
现在联系顾问~
热词
    • 1. 发明专利
    • PRESSURIZED FEEDWATER SYSTEM FOR INTERMEDIATE OR HIGH- RISE BUILDING
    • JP2000303514A
    • 2000-10-31
    • JP2000106837
    • 2000-04-07
    • HITACHI LTD
    • SATO KOICHIKUNII HIROSHI
    • E03B5/00E03B11/16E03C1/00
    • PROBLEM TO BE SOLVED: To provide a pressurized feedwater system for an intermediate or high-rise building capable of always effectively utilizing the feedwater pressure in the city water pipes with a simple structure and capable of sufficiently reducing the cost. SOLUTION: Water is supplied to the faucets 10a to 10c in the lower floors through a feedwater pipe 3 directly from a city water distributing pipe 1, and the feedwater for the faucets 10d to 10f in the higher floors is pressurized by a booster pump 4 whose suction pipe is connected to the feedwater pipe 3 and is fed through a feedwater pipe 8. Since the city water in the lower zone is fed only by the hydraulic pressure in the city water pipe, depressurization can be dispensed with, and the booster pump 4 is operated only to obtain the pressurization necessary for the higher zone, so that the hydraulic pressure in the city water pipe is sufficiently utilized. As a result, depressurization in the lower zone is unnecessary, so that necessary energy can be reduced, and the water supply to the lower zone can be constantly maintained even without a bypass line.
    • 4. 发明专利
    • PRESSURE-BOOSTING FEED WATER SYSTEM FOR MID-TO-HIGH-RISE BUILDING
    • JP2000303515A
    • 2000-10-31
    • JP2000106839
    • 2000-04-07
    • HITACHI LTD
    • SATO KOICHIKUNII HIROSHI
    • E03B5/00E03B11/16E03C1/00
    • PROBLEM TO BE SOLVED: To provide a pressure-boosting feed water system for a mid-to-high-rise building that has a simple arrangement, can make effective use of feed water pressure in a water pipe at any times, and can reduce costs sufficiently. SOLUTION: Water is fed directly from a city water distribution pipe 1 to faucets 10a-10c on lower stories via a feedwater pipe 3, and the feed of water to faucets 10d-10f on higher stories is effected via a feed water pipe 8 after pressure is boosted by a booster pump 4 whose suction pipe is connected to the feedwater pipe 3. Since water is fed to the lower-story zone by means of only the hydraulic pressure of a water pipe, the need for pressure reduction is eliminated, and since the booster pump 4 needs merely to work for providing the pressure boosting required for the higher-story zone, the hydraulic pressure of the water pipe is fully utilized, with the result that the energy required can be reduced as the need for pressure reduction in the lower-story zone is also eliminated. Also, the fear of water feed to the lower-story zone being interrupted can be eliminated even in the absence of a bypass line.
    • 7. 发明专利
    • AIR SUPPLY DEVICE FOR PRESSURE TANK TYPE WATER FEED EQUIPMENT
    • JPS6299696A
    • 1987-05-09
    • JP23764285
    • 1985-10-25
    • HITACHI LTD
    • KUNII HIROSHISATO KOICHI
    • F04B23/02F04D13/16
    • PURPOSE:To recover water in an air tank certainly, by setting a control valve which opens for a period of required recovery time calculated by a control part, to drive a jet pump, when it is detected by a detector that the air pressure in a pressure tank rises to the jet pump start air pressure, which was calculated by the control part. CONSTITUTION:A lift-up height H which is actually set by an operator, is input by means of an input part 13. The present air pressure in a pressure tank 4 is detected by a detector 14, and it is decided whether it rises above the jet pump start air pressure or not, which was calculated by a control part 20. When the detected air pressure is higher than the jet pump start air pressure, a control valve 12 is opened, through an output part 15, by closing an opening/closing switch 26 for a period of required recovery time, by the control part 20. In this way, as a jet pump 10 is driven, this pump 10 starts to recover the water in an air tank 5, while discharging the water in the pressure tank 4 to a water receive tank 1. Accordingly, the water in the air tank 5 can be recovered certainly, because the jet pump 10 is driven for a period of time which is calculated based on the relation between the air pressure in the pressure tank 4 and the lift-up height, even if the air pressure in the pressure tank 4 varies.
    • 8. 发明专利
    • WATER SUPPLY SYSTEM DIRECT-CONNECTED TO CITY WATER
    • JPH10259622A
    • 1998-09-29
    • JP5832498
    • 1998-03-10
    • HITACHI LTD
    • SATO KOICHIKUNII HIROSHI
    • E03B5/02E03B11/16
    • PROBLEM TO BE SOLVED: To save the energy of a water supply system used in direct connection with city water. SOLUTION: A water supply system comprises a water supply pipe 20 to feed water from a distributing pipe 1 to an end hydrant 22, at least one of the electric motor-driven pumps 10 and 11 which is installed in mid way to the water supply pipe 20 and delivers water to the end hydrant 22, an original pressure sensor 7 which is installed in the water supply pipe 20 in the upstream from the electric motor-driven pumps 10 and 11 and detects the original pressure of a water source, a low water level detecting means 23 and 24 which are installed in the water supply pipe 20 in the downstream from the electric motor-driven pumps 10 and 11 and detects low water level, and a delivery pressure sensor 18 for detecting delivery pressure. Also it is provided with a control means 21 which outputs those signals to stop the pumps 10 and 11 when the detected original pressure becomes a value exceeding that obtained by adding a specified resistance between both pressure sensors to a specified pressure on the delivery side and the low water level detecting means 23 and 24 detect the low water level, supply water directly by the pressure of the distributing pipe 1, and start the pumps 10 and 11 when the detected delivery pressure falls below a specified start pressure, and a drive means 21 to supply variable power to the electric-motor driven pumps 10 and 11 based on the signals from the control means 21.